APC Smart-UPS XL Modular 3000VA 230V Rackmount/Tower SUM3000RMXLI2U APC Smart-UPS XL, 3000VA/2850W, Input 230V/Output 230V, Interface Port DB-9 RS-232, RJ-45 10/100 Base-T, USB, Extended runtime model, Rack Height 2 U Includes: CD with software, Rack Mounting Brackets, Rack Mounting support rails, Smart UPS signalling RS-232 cable, USB cable, User Manual Features Automatic internal bypass Modular design Rack/Tower convertible Remote group outlet control USB connectivity User-replaceable batteries User-replaceable modules Output Output Power Capacity 2850 Watts / 3000 VA Max Configurable Power 2850 Watts / 3000 VA Nominal Output Voltage 230V Output Voltage Note Configurable for 220 : 230 or 240 nominal output voltage Efficiency at Full Load 89% Output Voltage Distortion Less than 5% at full load Output Frequency (sync to mains) 47 - 53 Hz for 50 Hz nominal,57 - 63 Hz for 60 Hz nominal Crest Factor up to 5 : 1 Waveform Type Sine wave Output Connections (7) IEC 320 C13 (1) IEC 320 C19 (4) IEC Jumpers Input Bypass Internal Bypass (Automatic and Manual) Nominal Input Voltage 230V Input Frequency 50/60 Hz +/- 5 Hz (auto sensing) Input Connections IEC-320 C20 Cord Length 10 feet ( 3.05 meters) Input voltage range for main operations 160 - 285V Input voltage adjustable range for mains operation 151 - 302V Batteries & Runtime Battery Type VRLA Included Battery Modules 1 Typical recharge time 3 hour(s) Replacement battery cartridge RBC43 RBC™ Quantity 1 Typical Backup Timeat Half Load 11.9 minutes (1425 Watts) Typical Backup Timeat Full Load 3.5 minutes (2850 Watts) Runtime Chart Smart-UPS XL Extended Run Options NEW! APC Smart-UPS XL Modular 3000VA 230V Rackmount/Tower Communications & Management Interface Port(s) DB-9 RS-232,RJ-45 10/100 Base-T,USB Pre-Installed SmartSlot™ Cards AP9619 Control panel LED status display with load and battery bar-graphs and On Line : On Battery : Replace Battery : Overload and Bypass Indicators Audible Alarm Alarm when on battery : distinctive low battery alarm : configurable delays Emergency Power Off (EPO) Optional Surge Protection and Filtering Surge energy rating 490 Joules Filtering Full time multi-pole noise filtering : 0.3% IEEE surge let-through : zero clamping response time : meets UL 1449 Physical Maximum Height 3.40 inches ( 86 mm) Maximum Width 17.00 inches (432 mm) Maximum depth 26.70 inches (678 mm) Rack Height 2U Net Weight 103.00 lbs. ( 46.82 kg) Shipping Weight 125.00 lbs. ( 56.82 kg) Shipping Height 9.84 inches (250 mm) Shipping Width 23.46 inches (596 mm) Shipping Depth 38.58 inches (980 mm) Color Black Units per Pallet 8.00 Environmental Operating Environment 32 - 104 °F (0 - 40 °C) Operating Relative Humidity 0 - 95% Operating Elevation 0-10000 feet (0-3000 meters) Storage Temperature -4 - 113 °F (-20 - 45 °C) Storage Relative Humidity 0 - 95% Storage Elevation 0-30000 feet (0-9000 meters) Audible noise at 1 meter from surface of unit 55 dBA Online Thermal Dissipation 300 BTU/hr Conformance Regulatory Approvals C-tick,CE,EN 50091-2,EN 55022 Class A,EN 61000-3-2,GOST Standard Warranty 2 years repair or replace