APC Smart-UPS RT, 3000VA/2100W, Input 120V/Output 120V, Interface Port DB-9 RS-232, Smart-Slot, Extended runtime model, Rack Height 3 U
Includes: CD with software, Smart UPS signalling RS-232 cable, User Manual
Product Overview
Availability
Automatic internal bypass
| Supplies utility power to the connected loads in the event of a UPS overload condition or fault.
|
Scalable runtime
| Allows additional run time to be quickly added as needed.
|
Intelligent battery management
| Maximizes battery performance, life, and reliability through intelligent, precision charging.
|
Hot-swappable batteries
| Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
|
Automatic restart of loads after UPS shutdown
| Automatically starts up the connected equipment upon the return of utility power.
|
Temperature-compensated battery charging
| Prolongs battery life by regulating the charge voltage according to battery temperature. |
Manageability
Network manageable
| Monitor and control the UPS and access environmental information remotely via included PowerChute software or APC's Network Management Card with temperature monitoring (included in all models above 3kVA).
|
InfraStruXure Manager compatible
| Enables centralized management via APC's InfraStruXure Manager.
|
SmartSlot
| Customize UPS capabilities with management cards.
|
LED status indicators
| Enables quick understanding and response to visual indicators showing UPS status.
|
Serial Connectivity
| Provides management of the UPS via a serial port. |
Adaptability
Plug-and-Play external batteries
| Ensures clean, uninterrupted power to the loads when adding extra runtime to the UPS.
|
Rack/Tower convertible
| Protects the initial investment in the UPS when migrating from tower to rack-mount environment.
|
Flash-upgradeable firmware
| Easy implementation of new firmware upgrades. |
Serviceability
User-replaceable batteries
| Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
|
Automatic self-test
| Periodic battery self-test ensures early detection of a battery that needs to be replaced.
|
Predictive failure notification
| Provides early-warning fault analysis ensuring proactive component replacement.
|
Disconnected battery notification
| Warns when a battery is not available to provide backup power.
|
Audible alarms
| Actively let you know if the unit is on battery, if the battery is low or if there is an overload condition. |
Protection
Frequency and voltage regulation
| Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.
|
Power conditioning
| Protects connected loads from surges, spikes, lightning, and other power disturbances.
|
Input power factor correction
| Minimizes installation costs by enabling the use of smaller generators and cabling.
|
Generator compatible
| Ensures clean, uninterrupted power to the loads in the event of an extended power outage
|
Cold-start capable
| Provides temporary battery power when the utility power is out.
|
Resettable circuit breakers
| Enables quick recovery from UPS overload events.
|
Safety-agency approved
| Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment. UL, FCC, CE, C-Tick approvals. |
Technical Specifications
Output Power Capacity
| 2100 Watts / 3000 VA
|
Max Configurable Power
| 2100 Watts / 3000 VA
|
Nominal Output Voltage
| 120V
|
Output Voltage Distortion
| Less than 3%
|
Output Frequency (sync to mains)
| 50/60 Hz +/- 3 Hz user adjustable +/- 0.1
|
Crest Factor
| 3 : 1
|
Waveform Type
| Sine wave
|
Output Connections
|
(6) NEMA 5-15R |
|
(2) NEMA 5-20R |
| |
Bypass
| Internal Bypass (Automatic and Manual)
|
Nominal Input Voltage
| 120V
|
Input Frequency
| 50/60 Hz +/- 5 Hz (auto sensing)
|
Input Connections
|
|
Cord Length
| 10 feet ( 3.05 meters)
|
Input voltage range for main operations
| 90 - 150V |
Battery Type
| Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof
|
Included Battery Modules
| 2
|
Typical recharge time
| 2.50 hour(s)
|
Replacement battery cartridge
|
RBC44
|
RBC™ Quantity
| 1
|
Typical Backup Time at Half Load
| 33.9 minutes (1050 Watts)
|
Typical Backup Time at Full Load
| 14.1 minutes (2100 Watts)
|
Runtime Chart
|
Smart-UPS RT
|
Extended Run Options
|
APC SMART-UPS RT 3000VA 120V |
Communications & Management
Interface Port(s)
| DB-9 RS-232,Smart-Slot
|
Available SmartSlot™ Interface Quantity
| 1
|
Control panel
| LED status display with load and battery bar-graphs and On Line : On Battery : Replace Battery : Overload and Bypass Indicators
|
Audible Alarm
| Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm
|
Emergency Power Off (EPO)
| Yes |
Surge Protection and Filtering
Surge energy rating
| 480 Joules
|
Filtering
| Full time multi-pole noise filtering : 0.3% IEEE surge let-through : zero clamping response time : meets UL 1449 |
Maximum Height
| 17.00 inches (432 mm)
|
Maximum Width
| 5.10 inches (130 mm)
|
Maximum depth
| 26.00 inches (660 mm)
|
Rack Height
| 3U
|
Net Weight
| 120.00 lbs. ( 54.55 kg)
|
Shipping Weight
| 140.00 lbs. ( 63.64 kg)
|
Shipping Height
| 13.68 inches (347 mm)
|
Shipping Width
| 23.73 inches (603 mm)
|
Shipping Depth
| 38.60 inches (980 mm)
|
Color
| Black
|
Units per Pallet
| 6.00 |
Operating Environment
| 32 - 104 °F (0 - 40 °C)
|
Operating Relative Humidity
| 0 - 95%
|
Operating Elevation
| 0-10000 feet (0-3000 meters)
|
Storage Temperature
| 5 - 113 °F (-15 - 45 °C)
|
Storage Relative Humidity
| 0 - 95%
|
Storage Elevation
| 0-50000 feet (0-15000 meters)
|
Audible noise at 1 meter from surface of unit
| 55 dBA
|
Online Thermal Dissipation
| 655 BTU/hr |
Regulatory Approvals
| CSA,FCC Part 15 Class A,UL 1778
|
Standard Warranty
| 2 years repair or replace |
**The time to recharge to 90% of full battery capacity following a discharge to shutdown using a load rated for 1/2 the full load rating of the UPS.
Uteffekt kapacitet (VA) | 3 kVA |
Uteffekt | 2100 W |
Ingångsfrekvens | 50/60 hz |
Energivärdering | 480 J |
Nödstopp (EPO) | Ja |
Ljudnivå Lc IEC | 55 dB |
Hörbart larm | Ja |
Batteriteknik | Slutna blybatterier (VRLA) |
Normal drifttid vid full belastning | 14,1 min |
Normal drifttid vid halv belastning | 33,9 min |
Laddningstid | 2,5 h |
Produktens färg | Svart |
Kabellängd | 3,05 m |
LED-indikatorer | Ja |
Certifiering | CSA,FCC Part 15 Class A,UL 1778 |
Temperatur vid drift | 0 - 40 ° C |
Temperaturintervall (förvaring) | -15 - 45 ° C |
Intervall för relativ operativ luftfuktighet | 0 - 95% |
Fuktighet (förvaring) | 0 - 95% |
Altitud vid drift | 0 - 3000 m |
Höjd över havet i avstängt läge | 0 - 15000 m |
Vikt | 54,5 kg |
Vikt inkl. förpackning | 63,6 kg |
Harmonized System (HS)-kod | 85078000 |
Gränssnitt | DB-9 RS-232, Smart-Slot |
Anslutningsdetaljer utgång | (6) NEMA 5-15R,
(2) NEMA 5-20R |
Anslutningsdetaljer ingång | NEMA L5-30P |
Produktstorlek (BxDxH) | 130 x 660 x 432 mm |
Utspänning (Volt) | 120 V |
Ingångsspänning (Volt) | 120 V |
Förpackningsstorlek (B x D x H) | 603 x 980 x 347 mm |
UPS & Power / Accessories
Även om vi gör vårt bästa för att ge relevant information, så är bilderna bara till för att ge ett generellt intryck, och själva varan behöver nödvändigtvis inte se ut precis som på bilden. Om det är skillnader mellan produktöverskrift, beskrivning och bild, så är det produktöverskriften som gäller. (tex. Pc:n kommer inte nödvändigtvis med monitor även om bilden visar det) Om något är oklart skicka en e-post till oss före du beställer! Vi förbehåller oss för tryckfel, ändringar av priser och specifikationer utan varsel.