Var god vänta...
Produkten har lagts till i kundvagnen. Se kundvagnen här

APC APC SERVICE BYPASS PANEL 230V 16A BBM Hardwire

Förstasidan UPS & Power UPS APC APC SERVICE BYPASS PANEL 230V 16A BBM Hardwire
Du måste logga in för att kunna handla/se priser.
APC APC SERVICE BYPASS PANEL 230V 16A BBM Hardwire (SBP3000RMHW)
APC APC SERVICE BYPASS PANEL 230V 16A BBM Hardwire (SBP3000RMHW)
APC APC SERVICE BYPASS PANEL 230V 16A BBM Hardwire (SBP3000RMHW)
APC APC SERVICE BYPASS PANEL 230V 16A BBM Hardwire (SBP3000RMHW)

APC APC SERVICE BYPASS PANEL 230V 16A BBM Hardwire

Artikelnr:
SBP3000RMHW
EAN:
0731304283225
  • Typ PDU
Beskrivning

APC SERVICE BYPASS PDU, 230V 16AMP Hardwire


APC Maintenance Bypass Panels , Input: 230V , Output: 230V , Output Connections: Hard Wire 3-wire (H N + G),IEC Jumpers

Output

Nominal Output Voltage: 230V
Maximum Total Current Draw per Phase: 16A
Output Connections: (1) Hard Wire 3-wire (H N + G) (1) IEC Jumpers
Overload Protection: Yes
Cord Length: 1 meters

Input

Nominal Input Voltage: 230V
Input Frequency: 50/60 Hz
Acceptable Input Voltage: 220-240 VAC
Maximum Line Current per phase: 16A
Maximum Input Current per phase: 16A
Load Capacity :3000 VA
Load Power Factor Range: 0 to 1

Physical

Net Weight: 2.27 KG
Maximum Height: 89.00 mm
Maximum Width: 432.00 mm
Maximum Depth: 76.00 mm
Shipping Weight: 3.45 KG
Shipping Height: 151.00 mm
Shipping Width: 463.00 mm
Shipping Depth: 295.00 mm
Color: Black
Units per Pallet: 56.00

Environmental

Operating Environment: 0 - 40 °C
Operating Relative Humidity: 0 - 95%
Operating Elevation: 0-4500 meters
Storage Temperature: -15 - 45 °C
Storage Relative Humidity: 0 - 95%
Storage Elevation: 0-15000 meters

Conformance

Regulatory Approvals: VDE
Standard Warranty: 2 years repair or replace
Environmental Compliance: RoHS,REACH: Contains No SVHCs

Features

Transfer rate is within the industry standard and within the time power supplies will typically drop loads. The transfer of one power source to another is seamless to the connected equipment avoiding disruption of equipment performance.

(3) Breaker maintenance bypass panel to isolate the UPS from the critical load

Även om vi gör vårt bästa för att ge relevant information, så är bilderna bara till för att ge ett generellt intryck, och själva varan behöver nödvändigtvis inte se ut precis som på bilden. Om det är skillnader mellan produktöverskrift, beskrivning och bild, så är det produktöverskriften som gäller. (tex. Pc:n kommer inte nödvändigtvis med monitor även om bilden visar det) Om något är oklart skicka en e-post till oss före du beställer! Vi förbehåller oss för tryckfel, ändringar av priser och specifikationer utan varsel.